Detailed Specification
- Up to 50 parameters - voltage, current, power, energy, demand, thd
- Accuracy maintained even on non-linear loads and fastswitching loads - 42 samples/ cycle & continuous cycle-bycycle sampling on all 3 voltage and 3 current inputs
- Compact size 96x96mm; depth is just 72mm
- Fully isolated CT inputs for user & installation safety
- Wide measurement range starting as low as 0.5%FS & high resolution display
- Modular design allows you to add features in the future
- Optional high speed RS-485 port with Modbus RTU protocol for communication with PC/ PLCs
- Expandable as remote I/O module with 4 digital inputs & 3 digital outputs
- Replaces transducers with optional 4-20 mA or 0-4V dc analog outputs
- Pulse outputs for PLC integration as standard feature
- PLM Cube 2 – Measures V, I, PF, kW, Hz, kWh
- PLM Cube 6 – Additionally measures kVA, kVAR, kVAh, +/-kVARh, Demands, V THD, I THD, Neutral Current New Generation Measurement technology
- High speed processor – samples at 42 samples/cycle maintaining accuracy by taking into account up to 20th order harmonic content
- Measures every single cycle on all 3 voltages and 3 currents and guarantees accuracy of readings even when the loads are dynamic and when the currents are very low. Easy to install & use
- Speedy installation – 4 sq. mm large rising cage terminals & easy mounting clips
- Auto-commissioning feature – takes care of CT reversals automatically; high resolution, low value measurements enables testing even on minimal loads
- All measurements available only on 4 buttons Excellent display
- Back-lit LCD 3-line display; Easy to view custom built alpha numeric display with 12mm digit height and 3.8mm legend height
- High resolution – 4 digits for phase-wise; 5 digits for 3-phase and 7 digits for energy
readings
- Auto ranging feature making it easily readable – W/ kW/ MW or V/ kV or A/ kA Peace of mind for user - ideal for Indian operating conditions
- Isolated CT inputs (2.5kV) – offers better protection and guarantees accurate
measurements
- Voltage overload – 2 times for 2 sec; Current overload – 40 times for 1 sec
- High IP rating – IP 54
- Ideal for Networks/ DCS/ SCADA systems
- High speed communications made possible by dedicated communications processor – up to 20 Load Managers can be read in a single second saving precious time & resources of the PLC
- Expands the scope of data acquisition & controls – offers optional module with 4 digital inputs & 3 digital outputs on the Load Manager for status monitoring, pulse counting & controls
- Optional analog outputs from the Load Manager can be integrated with a PLC (0-
20mA or 0-4Vdc)
- Two pulse outputs for energy pulsing
- Low initial investment – field upgradable modules to meet future needs – Options include RS-485, Digital I/O, Analog outputs
|