Home | Software | Contact Us | FAQ | Sitemap | Feedback   
     
  30KVA
  40KVA
  45KVA
  50KVA
  63KVA
  75KVA
  82.5KVA
  100KVA
  110KVA
  125KVA
  140KVA
  160KVA

TECHNICAL PARTICULARS OF KIRLOSKAR ELECTRIC BLISS DG SETS

DG SET Model 30K-3KSWTC105
RATING (KVA) 30
Rated kW 24
Rated Current (Amps) 42
LengthxwidthxHeight(mm) 2600x1250x1600
Total Dry Weight(Kgs) 1125
ENGINE Make KAYTEE
Model 3KSWTC105
BHP 46
No. of Cylinders 3
RPM 1500
Bore(mm) 105
Stroke(mm) 125
Displacement(ltrs) 3.25
Compression ratio 16:01
SFC (gms/BHP-hr) 158
Governor Mech
Class of Governing A
Aspiration TC
Air fitler Dry Type
Fuel HSD
Type of oil 20W/40W
Oil sump capacity(ltrs) 8
Lub Oil consumption (gms/BHP-hr) 1.2
Cooling WC / Radiator / Force Cooled
Bare Radiator water capacity(ltrs) 7
Water Capacity with engine Jacket(ltrs) 9
Engine Dry Weight(Kgs) 395
Electric Starting System 12V/24V
ALTERNATOR  Make KEC
Model 4AB180M1
Type Brushless
Rating(KVA) 30
Voltage(V) 415
No. of Phases 3
Power Factor 0.8
Speed (rpm) / Frequency (Hz) 1500/50
Voltage Regulation  
Enclosure SPDP
Insulation class H
Weight of ACG (Kgs) 210
CONTROL PANEL Type INBUILT
Metering Voltmeter, Ammeter, Frequency Meter, RPM Meter, Hour Meter(kW, kWH Meters OptionalUpto 63 kVA
Guages Fuel Level Indicator, Lub Oil Pressure, Water Temperature, Oil Temperature
Functions Start/Stop
Protection Short Circuit, Over Load
Safeties Low Lub Oil Pressure, High Water Temprature, Auto Shutdown, Visual&Audio AlarmAgainst Fault
BATTERY Make Exide
Type Dry Type
Rating(AH) 95
Quantity(Nos.) 1 or 2
Charging Facility Charging Alternator
Battery Metering Ammeter
EXHAUST SYSTEM Silencer type Residential
location TOP
Exhaust pipe size(inches) 3"
FUEL TANK Type INBUILT
Capacity (Liters) 90
CANOPY Type BOLTED
Sheetmetal CRCA
Draft NATURAL
Insulation FOAM/ROCK WOOL
Noise level at 1 m LESS THAN 75 DB
OTHER ITEMS Base frame Pressed CRCA Channel
AVMs Qty(Nos.) 5
Emergency stop YES
Internal Lights YES

 

     
  Krykard Energy MetersKrykard
Energy Meters